Half-life period
|
The number of seconds it takes for the penalty to reduce by half. The configurable range is 1-30 seconds. Default
value is 5 seconds.
|
|
Reuse Threshold
|
The value of the penalty at which the dampened interface is restored. The configurable range is 1-20,000. Default
value is 1000.
|
|
Suppress Threshold
|
The value of the penalty at which the interface is dampened. The configurable range is 1-20,000. Default value is
2000.
|
|
Max Suppress Time
|
The maximum amount of time (in seconds) an interface can be in suppressed state after it stops flapping. The
configurable range is 1-255 seconds. The default value is four times of half-life period. If half-period value is allowed to
default, the maximum suppress time defaults to 20 seconds.
|
|
Restart Penalty
|
Penalty applied to the interface after the device reloads. The configurable range is 1-20,000. Default value is
2000.
|