dot1x timeout

This command sets the value, in seconds, of the timer used by the authenticator or supplicant state machines on an interface or range of interfaces. Depending on the token used and the value (in seconds) passed, various timeout configurable parameters are set. The following tokens are supported:

Tokens Definition
quiet-period The value, in seconds, of the timer used by the authenticator state machine on this port to define periods of time in which it will not attempt to acquire a supplicant. This is the period for which the authenticator state machine stays in the HELD state.
tx-period The value, in seconds, of the timer used by the authenticator state machine on this port to determine when to send an EAPOL EAP Request/Identity frame to the supplicant.
server-timeout The value, in seconds, of the timer used by the authenticator state machine on this port to timeout the authentication server.
supp-timeout The value, in seconds, of the timer used by the authenticator state machine on this port to timeout the supplicant.
auth-period The value, in seconds, of the timer used by the supplicant state machine on this port to timeout an authenticator when waiting for a response to packets other than EAPOL-Start.
start-period The value, in seconds, of the timer used by the supplicant state machine on this port to determine the interval between two successive EAPOL-Start frames when they are being retransmitted.
held-period The value, in seconds, of the timer used by the supplicant state machine on this port to determine the length of time it will wait before trying to send the authentication credentials again after a failed attempt. This is the period for which the supplicant state machine stays in the HELD state.
Default
  • quiet-period: 60 seconds
  • tx-period: 30 seconds
  • supp-timeout: 30 seconds
  • server-timeout: 30 seconds
  • auth-period: 30 seconds
  • start-period: 30 seconds
  • held-period: 60 seconds
Format dot1x timeout {quiet-period seconds | tx-period seconds | supp-timeout seconds | server-timeout seconds | auth-period seconds | start-period seconds | held-period seconds}