neighbor shutdown

Use this command to bring down the adjacency with a specific neighbor. If the adjacency is up when the command is given, the peering session is dropped and all route information learned from the neighbor is purged.

When a neighbor is shut down, BGP first sends a NOTIFICATION message with a Cease error code. When an adjacency is administratively shut down, the adjacency stays down until administratively re-enabled (using the no neighbor shutdown command below).

Issue this command in Peer Template Configuration Mode to add it to a peer template.

Default Neighbors are not shutdown by default.
Format neighbor {ipv4-address | ipv6-address [interface interface-name]| autodetect interface interface-name } shutdown
Mode
  • BGP Router Config
  • Peer Template Config
Parameter Description
ipv4-address|ipv6-address The neighbor's IPv4 or IPv6 address on the link that connects the two peers.
autodetect interface interface-name The routing interface on which the neighbor's link local IPv6 address is auto-detected.

www.lancom-systems.com